3.4 Coil. Figure 14 illustrates the major parts involved in removing and replacing the
coil.
3004-0003 COIL KIT SVC F3
3004-0038 KIT SVC COIL RETAINER, contains pt 1 & 3
1 2004-0037 RETAINER COIL BLACK F3
2 2021-0054 COIL F3
3 4005-0039 BLOCK FRICTION COIL F3
4 8009-0007 RETAINER PLUG F3
5 4308-0012 PIN COIL CABLE
Figure 14: Coil
a. To remove the coil:
Retract the shafts and remove the battery pack.
Remove the electronics pack as described in Section 3.3.a. However, there is no
need to remove the electronics pack from the upper shaft.
Remove the coil plug retainer, if fitted, from around the coil plug. (Figure 15)
Allow the coil cable to retract into the shafts.
Figure 15: Removing Coil Plug Retainer
Maintaining firm downward pressure on the 6.5mm screwdriver, carefully lever the
coil retainer cover off the coil top and remove it. (Figure 16)